Improving Radiation Quality and Safety in the NICU Through the Implementation of a Standardized X-Ray Protocol

Loading...
Thumbnail Image

Issue Date

Volume

Issue

Type

Manuscript

Language

Keywords

Research Projects

Organizational Units

Journal Issue

Alternative Title

Abstract

Background: Diagnostic radiology is used for the diagnosis and management of neonatal disorders in neonatal intensive care units. Although it is currently a necessary component for proper care, increased exposure to radiation is associated with healthcare risks. Neonates are the most vulnerable population to radiation. On average, a neonate will be exposed to 0.3-1.24 mSV of radiation during a NICU stay, exceeding the recommended limit. Despite current x-ray standards, poor quality x-rays continue to be an existing problem, leading to increased radiation exposure and unnecessary manipulation of lines and tubes, including endotracheal tubes (ETTs).|Purpose: The purpose of this project is to implement a standardized x-ray protocol to improve the quality of x-rays and decrease ETT manipulations in a NICU.|Methods: This project took place in a 7-bed specialty unit for neonates born less than 29 weeks and admitted before 32 weeks. Phase 1 was a retrospective review of patient charts over a 15 week period. Data collected included total number of x-rays, x-ray quality, and number of ETT manipulations. A safety checklist was developed and placed at each patient bedside after staff education was completed. Post implementation data was collected over a 12 week period with the same criteria as phase 1.|Results: A total of 40 patients and 801 x-rays were included in this project. After implementation of the x-ray protocol, there was improvement seen in all measured outcomes. Average x-ray quality score improved by 11.7% with improvement seen in all 4 quality measures. Head positioning compliance improved by 11% and arm positioning compliance improved by 10%. Artifact and rotation compliance showed improvement but remained below 50% post implementation. There was a decrease seen in ETT repositioning and average number of x-rays per patient, despite a lower mean gestational age in the post implementation group.|Conclusion: Education and safety checklists are effective methods to improving x-ray quality and safety in a NICU. Improvement in x-ray quality can decrease overall radiation exposure and decrease ETT manipulations. It is necessary to continue exploring best practices when performing and measuring the quality of neonatal images.

Description

Citation

Publisher

Creighton University

License

Copyright is retained by the Author. A non-exclusive distribution right is granted to Creighton University

Journal

Volume

Issue

PubMed ID

DOI

Identifier

Additional link

ISSN

EISSN

Endorsement

Review

Supplemented By

Referenced By